Fixes #2531: VFAS id 0x39: was 10x to small
Fixes #2530: VFAS id 0x3A and 0x3B: wrong calculation of value
This commit is contained in:
@@ -601,7 +601,7 @@ void processHubPacket(uint8_t id, int16_t value)
|
||||
}
|
||||
else if (id == VOLTS_AP_ID) {
|
||||
if (lastId == VOLTS_BP_ID) {
|
||||
data += lastValue * 100;
|
||||
data = ((lastValue * 100 + value * 10) * 210) / 110;
|
||||
unit = UNIT_VOLTS;
|
||||
precision = 2;
|
||||
}
|
||||
@@ -639,6 +639,9 @@ void processHubPacket(uint8_t id, int16_t value)
|
||||
if (id == RPM_ID) {
|
||||
data = data * 60;
|
||||
}
|
||||
else if (id == VFAS_ID) {
|
||||
data *= 10;
|
||||
}
|
||||
|
||||
setTelemetryValue(TELEM_PROTO_FRSKY_D, id, 0, data, unit, precision);
|
||||
}
|
||||
|
||||