fix: RX stat labelling dependent on telemetry protocol (#3523)
* RX stat (formerly known as "RSSI") labeling dependent on protocol (RSSI/dbm, Rqly/%, Sgnl/-) used for range check, multi rf tuning and low/critical warning settings pages * chore: Bump libopenui * removed define that was supposed to be for testing only function getRxStatLabels(): wasting flash as inline, no need to be inlined * removed inline on getRxStatLabels() - step 2
This commit is contained in:
@@ -72,6 +72,8 @@ static uint8_t intTelemetryRxBuffer[TELEMETRY_RX_PACKET_SIZE];
|
||||
static uint8_t intTelemetryRxBufferCount;
|
||||
#endif
|
||||
|
||||
static rxStatStruct rxStat;
|
||||
|
||||
uint8_t * getTelemetryRxBuffer(uint8_t moduleIdx)
|
||||
{
|
||||
#if defined(INTERNAL_MODULE_SERIAL_TELEMETRY)
|
||||
@@ -90,6 +92,60 @@ uint8_t &getTelemetryRxBufferCount(uint8_t moduleIdx)
|
||||
return telemetryRxBufferCount;
|
||||
}
|
||||
|
||||
rxStatStruct *getRxStatLabels() {
|
||||
// default to RSSI/db notation
|
||||
rxStat.label = STR_RXSTAT_LABEL_RSSI;
|
||||
rxStat.unit = STR_RXSTAT_UNIT_DBM;
|
||||
|
||||
// Currently we can only display a single rx stat in settings/telemetry.
|
||||
// If both modules are used we choose the internal one
|
||||
// TODO: have to rx stat sections in settings/telemetry
|
||||
uint8_t moduleToUse = INTERNAL_MODULE;
|
||||
|
||||
if(g_model.moduleData[INTERNAL_MODULE].type == MODULE_TYPE_NONE &&
|
||||
g_model.moduleData[EXTERNAL_MODULE].type != MODULE_TYPE_NONE) {
|
||||
moduleToUse = EXTERNAL_MODULE;
|
||||
}
|
||||
|
||||
uint8_t moduleType = g_model.moduleData[moduleToUse].type;
|
||||
|
||||
switch(moduleType) {
|
||||
case MODULE_TYPE_MULTIMODULE: {
|
||||
uint8_t multiProtocol = g_model.moduleData[moduleToUse].multi.rfProtocol;
|
||||
|
||||
if (multiProtocol == MODULE_SUBTYPE_MULTI_FS_AFHDS2A ||
|
||||
multiProtocol == MODULE_SUBTYPE_MULTI_HOTT ||
|
||||
multiProtocol == MODULE_SUBTYPE_MULTI_MLINK) {
|
||||
rxStat.label = STR_RXSTAT_LABEL_RQLY;
|
||||
rxStat.unit = STR_RXSTAT_UNIT_PERCENT;
|
||||
}
|
||||
}
|
||||
break;
|
||||
|
||||
case MODULE_TYPE_CROSSFIRE:
|
||||
case MODULE_TYPE_GHOST:
|
||||
rxStat.label = STR_RXSTAT_LABEL_RQLY;
|
||||
rxStat.unit = STR_RXSTAT_UNIT_PERCENT;
|
||||
break;
|
||||
|
||||
case MODULE_TYPE_FLYSKY:
|
||||
#if defined (PCBNV14)
|
||||
extern uint32_t NV14internalModuleFwVersion;
|
||||
|
||||
if(moduleToUse == INTERNAL_MODULE) {
|
||||
if(g_model.moduleData[INTERNAL_MODULE].subType == FLYSKY_SUBTYPE_AFHDS2A &&
|
||||
NV14internalModuleFwVersion >= 0x1000E) {
|
||||
rxStat.label = STR_RXSTAT_LABEL_SIGNAL;
|
||||
rxStat.unit = STR_RXSTAT_UNIT_NOUNIT ;
|
||||
}
|
||||
}
|
||||
#endif
|
||||
break;
|
||||
}
|
||||
|
||||
return &rxStat;
|
||||
}
|
||||
|
||||
// TODO: move to module port driver
|
||||
//
|
||||
// static int (*_telemetryGetByte)(void*, uint8_t*) = nullptr;
|
||||
|
||||
Reference in New Issue