Re #3371: tx battery measuring code moved to board_xxx.cpp, battery check code rewritten for ARM platforms, Horus battery calibrated.

This commit is contained in:
Damjan Adamic
2016-03-20 16:05:27 +01:00
parent 49e70dbf12
commit a3af63edad
8 changed files with 95 additions and 15 deletions
@@ -316,3 +316,11 @@ void checkTrainerSettings()
}
}
}
uint16_t getBatteryVoltage()
{
int32_t instant_vbat = anaIn(TX_VOLTAGE); // using filtered ADC value on purpose
instant_vbat = (instant_vbat * BATT_SCALE * (128 + g_eeGeneral.txVoltageCalibration) ) / 26214;
instant_vbat += 20; // add 0.2V because of the diode TODO check if this is needed, but removal will beak existing calibrations!!!
return (uint16_t)instant_vbat;
}
@@ -268,6 +268,7 @@ void adcInit(void);
void adcRead(void);
extern uint16_t adcValues[NUMBER_ANALOG];
uint16_t getAnalogValue(uint8_t index);
uint16_t getBatteryVoltage(); // returns current battery voltage in 10mV steps
#define BATT_SCALE 150